Charged from a 230v standard mains socket power or from a 12v Car charger
This battery's UPS capabilities, low fan noise and added protection against temperature, moisture, overload and short circuit, provide clean and cableless power in a small portable powerbank. They can be charged from 230v standard mains socket power or from a 12v Car charger.
VoltPax VXL3000 3kWh Battery
Weighing less than 30kg this VoltPax VXL3000 can, for example, run an ARRI S60-C Sky Panel at 100% Output for nearly 6 Hours Without a break. (The ARRI S60-C runs at 450w)
VPX5000 5Kwh Battery (5000w Inverter)
Output
AC output |
Rated current 16A |
Rated voltage |
220VAC |
Efficiency |
≥88% |
Overload capacity |
3000W<load<3500W,2min 6000W<load immediately |
Short circuit protection |
Yes |
Over temperature protection |
Yes |
Noise |
Load>3000W.Max.60dB |
DC12V/10A output |
Rated voltage 12V |
Rated current |
10A |
Overload power |
>120W .1S |
Short circuit protection |
Yes |
USB output |
Rated voltage 5V |
Current |
5V/3A 9V/2A 12V/1.5A |
Short circuit protection |
Yes |
XT90 Connector |
Rated current 30A |
Rated voltage |
220V |
Overload capacity |
5000W<load<5250W,2min 8000W<load immediately |
Input
AC output |
Maximum charging power 960W |
Charging time |
≥8h |
Solar charging |
Input voltage 48~56V |
Maximum circuit |
20A |
Maximum charging power |
960W |
Charging time |
>24h |
Remarks: It supports charging while discharging, and does not support UPS function.
Battery Pack
Battery option |
Lithium iron phosphate |
Nominal Capacity |
100Ah |
Nominal Voltage |
51.2V |
Max Charging Voltage |
58.4V (16 series) |
Life cycle |
2000 cycles |
Protection |
Discharge & charging, Over current protection, Over voltage protection, Low voltage protection, Short circuit protection, High temperature protection, low temperature protection |
Inverter
Wave Form |
Pure Sine Wave |
Continuous output |
5000W |
Output voltage |
AC 220V |
Output current |
22A |
Rated output frequency |
50HZ |
Efficiency |
90% |
Input Voltage |
46V±0.2V~56V±0.2V |
Charging rated current |
20A |
Protection |
Low voltage protection, Over voltage protection, Over load protection, Short circuit protection, Over temperature protection, Over current protection |
Protection Circuitry Function
Low voltage protection |
When the battery voltage is lower than DC46V, the output will be turned off and warm. The voltage recovery to 52V, it will restart automatically. DC46±0.5V |
Over voltage protection |
When the battery voltage is higher than DC58V, the output will be turned off and warn, and once the voltage recovery to 56V, it will restart automatically. DC58V±0.5V |
Over load protection |
When the 0utput is overload, power over 5000W, the product will turn off the corresponding output, and then it will automatically start thrice (at an interval of 10s). If there is still an overload, over-current or short circuit alarm, the output will be locked, and it needs to be manually troubleshooting and then restart. If the output stops repeatedly after restart, please stop using it immediately (only after troubleshooting) or contact the seller or maintenance agent for help. 5000W±50W |
Short circuit protection |
When the output is Short circuit, the product will turn off the corresponding output within 100uS, and then it will automatically start thrice. If there is still an overload, over-current or short circuit alarm, the output will be locked, and it needs to be manually troubleshooting and then restart. If the output stops repeatedly after restart, please stop using it immediately (only after troubleshooting) or contact the seller or maintenance agent for help. 50~100uS |
Over temperature protection |
When internal radiator temperature ≥40°C; cooling fan start cooling. ≥40°C±5°C |
Efficiency |
90% |
Input Voltage |
46V±0.2V~56V±0.2V |
Once the internal radiator temperature ≥80°C to turn off the output, the internal radiator temperature to restore to 60°C, then automatically restart |
≥80°C±5°C |
Charging protection |
Once the battery voltage is over than 58V, the charging connection is automatically cut off, and when the battery voltage drop to 56V, then the connection is automatically restored |